Toolbar

It contains the following control elements:

  • Filtration Filtration: show/hide Filtration panel.
  • Detailing Detailing: show/hide Detailing panel.
  • Detailing method: switch the Detailing display options. When pressing the button, the cyclic change of the Detailing methods is performed, and the Detailing method can be switched in the drop-down menu when pressing Open button. Detailing methods:
    • Table Table.
    • Form Form.
    • Statistics Statistics.
  • Indicator: switch the display options of Indicators. When pressing the button, the cyclic change of Indicators is performed, and also Indicator can be switched in the drop-down menu when pressing Open button. List of Indicators:
    • Importance Importance.
    •  Histogram Histogram.
    • Minimum Minimum.
    • Maximum Maximum.
    • Average Average.
    • Sum Sum.
    • Standard deviation Standard deviation.
    • Range Range.
    • Null count Null count.
    • Values Values.
    • Count of unique values Count of unique values.
    • Cluster center Cluster center.
  • Importance by color Importance by color: show/hide importance as the heat map. This option is reset and becomes inactive when Histogram indicator is selected.
  • Show null column in histograms Show null column in histograms: show/hide null column. The column visibility with null data is changed in the Main table and Cluster comparison panel histograms.
  • Show "Other" column in histograms Show "Other" column in histograms: show/hide Other column. In the discrete histograms of the Main table visibility of Other column is changed.
  • Show universal set in histograms Show universal set in histograms: show/hide the universal set.
  • Histogram scaling: switch the histogram scaling mode. When pressing the button, the cyclic change of histogram scaling modes is performed. It is also possible to switch the mode in the drop-down menu when pressing Open button. List of the Scaling Modes:
    • Absolute frequencies Absolute frequencies: the columns display the real number of values. The universal set columns are always higher or equal to the cluster columns.
    • Relative frequencies Relative frequencies: the universal set columns are equal and stretched to the cell height. Cluster columns have the following height: Number of values in the column/Number of values in the universal set column.
    • Density (PDF) Density (PDF): histograms of cluster and universal set are not connected with each other and have the same area. Histograms in the table cell or in the comparison tab are normalized by the height of the highest column.
  • Cluster position in table: switch cluster position in the table. When pressing the button, the cyclic change of cluster positions in the table is performed. And it is also possible to change cluster position in the table in the drop-down menu when pressing Open button. The following positions of clusters are possible:
    • Clusters in rows Clusters in rows.
    • Clusters in columns Clusters in columns.

results matching ""

    No results matching ""